Schneider Electric Acti9 Pro iDPNa-S miniature circuit breaker for overload protection, short-circuit protection and control of terminal circuits. It can disconnect both phase and neutral conductors, with isolation protection function
Schneider Electric Acti9 Pro iDPNa-S miniature circuit breaker is designed for terminal distribution circuits, providing overload protection, short-circuit protection and circuit control. The product can disconnect both the phase conductor and the neutral conductor at the same time, while the neutral conductor does not provide protection. It is suitable for low-voltage distribution applications in residential buildings, commercial buildings and terminal distribution boxes.
The product complies with GB10963.1 and IEC 60898-1 standards, and supports isolation protection function. It adopts a 1P+N pole configuration, with a rated current range of 6–40A, operating voltage of 230V, breaking capacity of 4500A, and service breaking capacity Ics of 100%.
The product supports C and D tripping curves, allowing selection according to different load types. The circuit breaker body has an IP20 protection rating, and can reach IP40 when installed inside a distribution box. It provides stable electrical and mechanical endurance.
- Overload protection
- Short-circuit protection
- Isolation protection
- Circuit control
- Disconnects both phase and neutral conductors
- Neutral conductor does not provide protection
- C and D tripping curves
- Suitable for terminal distribution circuits
Specifications
Certifications and Standards
Item
Description
National Standard
GB10963.1
International Standard
IEC 60898-1
Certification Marks
CCC, CE
Breaking Capacity Parameters
Poles
Operating Voltage Ue
Rated Current In
Breaking Capacity Icn
Service Breaking Capacity Ics
Ph/N, 1P+N
230V
6–40A
4500A
100%
Wiring Parameters
Screw Size
Rated Torque
Limit Torque
Copper Solid Wire
Copper Flexible Wire or Ferruled Terminal
M4.2
2 N·m
3.5 N·m
1–16 mm²
1–16 mm²
Main Technical Parameters
Parameter
Specification
Insulation Voltage Ui
400 V AC
Pollution Degree
2
Rated Impulse Withstand Voltage Uimp
4 kV
Reference Setting Temperature
30°C
C Curve Tripping Range
5–10 In
D Curve Tripping Range
10–14 In
Utilization Category
A
Current Limiting Class
3
Other Parameters
Parameter
Specification
Protection Rating, Circuit Breaker Body
IP20
Protection Rating, Installed in Distribution Box
IP40
Insulation Class
II
Electrical Endurance
>20A: 10,000 cycles; ≤20A: 20,000 cycles
Mechanical Endurance
20,000 cycles
Overvoltage Category IEC 60364
II
Operating Ambient Temperature
-25°C to +60°C
Storage Ambient Temperature
-40°C to +80°C
Damp Heat Resistance IEC 60068-1
Class 2, relative humidity 95% at 55°C
Weight Parameters
Type
Weight
iDPNa-S 1P+N
122 g